Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros

Base de datos
Tipo del documento
Intervalo de año
1.
Microbiol Spectr ; : e0213322, 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: covidwho-2108227

RESUMEN

The genome of the Omicron variant of concern (VOC) contains more than 50 mutations, many of which have been associated with increased transmissibility, differing disease severity, and the potential to elute immune responses acquired after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination or infection with previous VOCs. Due to a better tropism for the upper respiratory tract, it was suggested that the detection of the Omicron variant could be preferred in saliva, compared to nasopharyngeal swabs (NPS). Our objective was to compare the SARS-CoV-2 levels in saliva fluid and NPS to estimated Ct values, according to the main SARS-CoV-2 variants circulating in France since the beginning of 2021. We analyzed 1,289 positive reverse transcription-polymerase chain reaction (RT-PCR) results during the three major waves: Alpha, Delta, and Omicron. NPS and saliva sampling were performed for 909 (71%) and 380 (29%) cases, respectively. The Ct values were significantly lower in the NPS samples than in the saliva samples for the three main VOCs. Still, the difference was less pronounced with the Omicron variant than for the Alpha and Delta variants. In contrast, in the saliva samples, Ct values were significantly lower for the Omicron variant than for the Delta (difference of -2.7 Ct) and the Alpha (difference of -3.0 Ct) variants, confirming a higher viral load in saliva. To conclude, the higher viral load in saliva was evidenced for the Omicron variant, compared to the Alpha and Delta variants, suggesting that established diagnostic methods might require revalidation with the emergence of novel variants. IMPORTANCE Established methods for SARS-CoV-2 diagnostics might require revalidation with the emergence of novel variants. This is important for screening strategy programs and for the investigation of the characteristics of new variants in terms of tropism modification and increased viral burden leading to its spread. SARS-CoV-2 RT-PCR screening on saliva samples reported lower but acceptable performance, compared to nasopharyngeal samples. Due to a better tropism for the upper respiratory tract, it was suggested that the detection of the Omicron variant could be preferred in saliva, compared to nasopharyngeal swabs. Our study analyzed 1,289 positive RT-PCR results during the three major waves in France: Alpha, Delta, and Omicron. Our findings also showed a higher viral load in saliva for the Omicron variant, compared to the Alpha and Delta variants.

2.
Am J Infect Control ; 49(10): 1324-1326, 2021 10.
Artículo en Inglés | MEDLINE | ID: covidwho-1309130

RESUMEN

An outbreak of Klebsiella pneumoniae producing the carbapenemase NDM-1 occurred in our ICU during the last COVID-19 wave. Twelve patients were tested positive, seven remained asymptomatic whereas 5 developed an infection. Resistome and in silico multilocus sequence typing confirmed the clonal origin of the strains. The identification of a possible environmental reservoir suggested that difficulties in observing optimal bio-cleaning procedures due to workload and exhaustion contributed to the outbreak besides the inappropriate excessive glove use.


Asunto(s)
COVID-19 , Infecciones por Klebsiella , Antibacterianos , Proteínas Bacterianas/genética , Brotes de Enfermedades , Sueños , Humanos , Unidades de Cuidados Intensivos , Infecciones por Klebsiella/epidemiología , Klebsiella pneumoniae/genética , Pruebas de Sensibilidad Microbiana , Tipificación de Secuencias Multilocus , Pandemias , SARS-CoV-2 , beta-Lactamasas/genética
3.
Int J Infect Dis ; 108: 568-573, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: covidwho-1298674

RESUMEN

OBJECTIVES: This study aimed to evaluate the performance of FilmArray Pneumonia Panel Plus (FA-PP) for the detection of typical bacterial pathogens in respiratory samples from patients hospitalized in intensive care units (ICUs). METHODS: FA-PP was implemented for clinical use in the microbiology laboratory in March 2020. A retrospective analysis on a consecutive cohort of adult patients hospitalized in ICUs between March 2020 and May 2020 was undertaken. The respiratory samples included sputum, blind bronchoalveolar lavage (BBAL) and protected specimen brush (PSB). Conventional culture and FA-PP were performed in parallel. RESULTS: In total, 147 samples from 92 patients were analysed; 88% had coronavirus disease 2019 (COVID-19). At least one pathogen was detected in 46% (68/147) of samples by FA-PP and 39% (57/147) of samples by culture. The overall percentage agreement between FA-PP and culture results was 98% (93-100%). Bacteria with semi-quantitative FA-PP results ≥105 copies/mL for PSB samples, ≥106 copies/mL for BBAL samples and ≥107 copies/mL for sputum samples reached clinically significant thresholds for growth in 90%, 100% and 91% of cultures, respectively. FA-PP detected resistance markers, including mecA/C, blaCTX-M and blaVIM. The median turnaround time was significantly shorter for FA-PP than for culture. CONCLUSIONS: FA-PP may constitute a faster approach to the diagnosis of bacterial pneumonia in patients hospitalized in ICUs.


Asunto(s)
COVID-19 , Neumonía Bacteriana , Neumonía , Adulto , Bacterias , Humanos , Unidades de Cuidados Intensivos , Neumonía Bacteriana/diagnóstico , Estudios Retrospectivos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA